Associated Security Corporation
Associated Security Corporation
  • Home
  • About
  • Our Services
  • Who We Serve
    • Commercial & Industrial
    • Residential
    • Municipal
    • Educational
    • Storage Facilities
    • Banking and Finance
    • Pharmaceutical
  • Contact
  • Login
    • iBridge Connected Home
    • My Remote Keypad
    • Total Connect 2.0
    • Alarm.com
    • PDK DOOR ACCESS
    • DW SPECTRUM CLOUD
    • DMP VIRTUAL KEYPAD
  • Payments
  • Support
    • FAQ
    • User Guides
    • Forms
  • More
    • Home
    • About
    • Our Services
    • Who We Serve
      • Commercial & Industrial
      • Residential
      • Municipal
      • Educational
      • Storage Facilities
      • Banking and Finance
      • Pharmaceutical
    • Contact
    • Login
      • iBridge Connected Home
      • My Remote Keypad
      • Total Connect 2.0
      • Alarm.com
      • PDK DOOR ACCESS
      • DW SPECTRUM CLOUD
      • DMP VIRTUAL KEYPAD
    • Payments
    • Support
      • FAQ
      • User Guides
      • Forms
  • Home
  • About
  • Our Services
  • Who We Serve
    • Commercial & Industrial
    • Residential
    • Municipal
    • Educational
    • Storage Facilities
    • Banking and Finance
    • Pharmaceutical
  • Contact
  • Login
    • iBridge Connected Home
    • My Remote Keypad
    • Total Connect 2.0
    • Alarm.com
    • PDK DOOR ACCESS
    • DW SPECTRUM CLOUD
    • DMP VIRTUAL KEYPAD
  • Payments
  • Support
    • FAQ
    • User Guides
    • Forms

Napco MA1054E Style Keypad

HOW TO DISARM:
Enter your code into the keypad, if you enter a wrong code, you must wait at least 2 seconds before you try again.

HOW TO RESET:
Hold down 9 key till it beeps.

HOW TO CHANGE USER CODE:
Hold down the 8 key till it beeps. Enter your program code into keypad, the top 3 lights will flash and sounder will pulse. Press B or S key enter user # (1-5) then enter 4 digit code (1-9). 

EX: press (B/S) + 1 + four digits - user 1's code. To erase code press B/S plus user # (1-5) to be erased. 

EX: press (B/S) + 2 - user 2's code erased. to end program mode press B/S key twice.

TO BYPASS:
Hold down the number 9 until it beeps, then enter the code to arm or press B or S and then zone number to bypass and then enter the code to arm.

FLASHING GREEN LIGHT:
This means a zone is open or in trouble, hold down the number 3 key to display zone then try to close and reset. If unable to restore zone in trouble then press (b or s) key & the number of the zone (1-8) to be bypassed. Hold down the 2 key to display the bypassed zone(s).
 

Keypad says "P" and making noise:  

To clear a "P" from your keypad display and silence the tone:  enter your code.


SYSTEM TROUBLE CODES - 3 FLASHING LIGHTS:  

If your keypad is flashing numbers, note which ones.  If it is flashing lights, note which ones.  If it is flashing 3 lights AND numbers at the same time hold down the 9 button for 5 seconds.  Then look at the list below to troubleshoot.


1- AC Fail

2- Low battery

3- Communication Fail (You can hold down the 6 to check for dial tone and possibly clear this trouble. If that doesn't work, you need to test a signal through.)


Note:

If there has been a short term or intermittent issue with communication such as "Comm Fail" you can call the central station. put your system on test and intentionally trip the panic to test a signal through.

Download User Guide